by rgalajda » Fri Dec 01, 2023 12:58 pm
This is the 80’s single main air bleed version of the Quadrajet casting with the rear vacuum pull off. Rebuild kit would be SMP 1633 ( Standard Motor Products )
74 main jet / .044J Primary Rod / .0570 Secondary Rod / J hanger
Problems found.
Float level was .644”
No springs on primary rods
APT adjusted to 1/2 turn from bottomed
Air door was sticking ---- fixed
Idle bypass air not drilled in main body ---- fixed
Electric choke sticking in housing ----- fixed with bushing
Main body has an interference problem with baseplate -- Requires machining ----- fixed
Secondary disc for secondary metering rods ( in main body ) – one of them is not formed correctly
Secondary air valve spring tension was 1.5 turns ------ fixed
Primary blades not opening far enough , Secondary blades opening to far ----- fixed
I will post some picture later.
This will be 800cfm when I’m done.